Introduce
SLP-1000 is able to measure stress distribution of chemically tempered glass which is strengthened by ion-exchange from Li+ to Na+ using scattered light photoelectricity. In case of that the glass is strengthened by mixed liquid KNO3 and NaNO3, K+ layer should be measured by FSM6000 and Na+ layer should be measured by SLP-1000. These data can be combined by specialized software.
*The combination requires optional FsmV dongle
Feature
Model |
Wavelength |
CT-CV |
DOL-Zero |
SLP-1000 |
640nm |
5.65Mpa |
2.16㎛ |
SLP-2000 |
520nm |
1.51Mpa |
1.42㎛ |
SLP-2000 |
405nm |
1.00Mpa |
1.27㎛ |
- Actual data measuring the standard glass 20 times
- Required Refractive index and photoblastic constant at the wavelength for measurement
Specification
Meas Range |
CS 0-2000Mpa, DOL 10-400㎛ |
Meas Resolution |
Stress 5Mpa Depth 5㎛ |
Meas Precision |
50㎛ or deeper from surface Stress± 10Mpa Depth±10㎛ |
(For standard glass) |
Light source |
LD Wavelength 640±10nm 30mw Class 3B |
Application |
Chemically tempered glass, DIOX glass |
|
Thermally tempered glass |
Sample shape |
Flat-1000R 10x10mm or more |
Prism |
nD=1.516 |
PC |
Pre-installed OS, specialized software |
OS |
Windows 10 professional edition |
Size(main body) |
320x280x220mm |
Weight( main body) |
10kg |