Simple desktop oxygen monitor OXY-1/OXY-1S
Equipped with a galvanic battery type oxygen sensor, this is a small, simple and easy-to-use product that can be used for a wide range of oxygen concentration measurement.
★OXY-1S can be used JKO-Ver3 inline BF-JK.
★If this product is placed in an environment with high concentration of carbon dioxide gas for a long time, the lifespan of the sensor may be shortened.
Please use OXY-2 in such an environment.
Precaution: This is not a gas alarm. Please do not use it as a safety measure.
Specification | |||
Detected gas | Oxygen | ||
Detection principle | Galvanic battery | ||
Measuring range | 0.0~25.0vol% | ||
Resolution | 0.1vol% | ||
Measurement accuracy | ±0.5vol% | ||
Operating temperature | 0~40℃ | ||
Operating humidity | 0~95%RH | ||
Power supply | Alkaline AAA batteries 2Pcs | ||
Battery life | 1 year | ||
Size | 55x88x35.5mm | ||
Mass OXY-1 | 118g | ||
OXY-1S | 88g | ||
Sensor cable | 150g |
Simple desktop oxygen monitor with CO2 tolerance sensor OXY-2
By installing a galvanic battery type sensor that is resistant to CO2 (carbon dioxide), it can be used in an anaerobic closed space and nutrition experiment.
※This product is a disposable product.
Please note that we do not accept sensor exchanges.
Precaution: This is not a gas alarm.Please do not use it as a safety device.
Specifiactions | |||
Detected gas | Oxyen | ||
Detection principle | Galvanic battery | ||
Measuring range | 0.0~25.0vol% (service range 25~100vol%) |
||
Resolution | 0.1vol% | ||
Measurement accuracy | ±0.5vol%(0~25vol%) | ||
Operating temperature | 5~40℃ | ||
Operating humidity | 10~90%RH | ||
Power supply | Alkaline AAA batteries 2Pcs | ||
Battery lifespan | 1 year | ||
Expected sensor lifespan | 3 years | ||
Size | 55x88x35.5mm | ||
Mass OXY-1-M | 140g | ||
OXY-1S-M | 88g | ||
Sensor cable | 173g |
High concentration oxygen monitor OXY-1-M/OXY-1S-M
It is a product specialized for high-concentration specification that can extend the expected lifespan of the sensor and reduce running costs.
★OXY-1S can be used with JKO-Ver3 inline BF-JK.
Precaution: This is not a gas alarm.Please do not use it as a safety device.
Specification | |||
Detected gas | Oxygen | ||
Detection principle | Galvanic battery | ||
Measuring range | 0.0~100vol% (service range 25~100vol%) |
||
Resolution | 0.1vol% | ||
Measurement accuracy | ±0.5vol% | ||
Operating temperature | 0~40℃ | ||
Operating humidity | 0~95%RH | ||
Power supply | Alkaline AAA batteries 2Pcs | ||
Battery lifespan | 1 year | ||
Size | 55x88x35.5mm | ||
Mass | 110g |
Option BF-JK
Application: | |||
Used in combination with OXY-1S or OXY-1S-M to measure oxygen concentration in tubes and piping. |
Accessory: | |||
Separate sensor (curl cord about 1.75m) |